Rebar Calculator
Estimate how many rebar sticks you need for a concrete slab grid, with total linear feet, weight in pounds and tie wire count, by bar size and spacing.
Add this calculator to your website — get the free widget
How to Calculate
Bars running the length of the slab = slab width in inches ÷ spacing, rounded down, plus one for the far edge. Do the same the other way. Multiply each count by the length of the run and add them up for total linear feet.
Lap splices are handled as a flat percentage. A #4 bar lapped 40 bar diameters needs about 20 in of overlap at every joint; on a slab built from 20 ft sticks that works out to roughly 8–10% extra. Waste covers offcuts and bars bent wrong.
Weight = linear feet × weight per foot: #3 is 0.376 lb/ft, #4 is 0.668 lb/ft and #5 is 1.043 lb/ft. Tie wire is counted as one tie at every crossing; many crews tie every other crossing on slabs, which halves the number.
See our methodology for how every calculator on this site is built.
Worked Example: A 20 × 20 ft Garage Slab
A two-car garage slab, 20 ft by 20 ft, reinforced with #4 bar on 12 inch centers both ways. Bar comes in 20 ft sticks. We'll allow 10% for lap splices and 5% for waste.
- Bars running the 20 ft length: 240 in ÷ 12 = 20 spaces, plus 1 = 21 bars
- Bars running the 20 ft width: also 21 bars
- Linear feet before laps: 21 × 20 + 21 × 20 = 840 ft
- With laps and waste: 840 × 1.10 × 1.05 = 970 ft
- Sticks: 970 ÷ 20 = 48.5, so 49 bars
- Weight: 970 × 0.668 = 648 lb
- Crossings: 21 × 21 = 441 ties if you tie every one
A run that is exactly as long as the stick doesn't need a lap at all, so on this slab the 10% is a cushion for cuts at the edges and the bars you'll inevitably trim to clear a drain or a column pad. On a slab longer than the stick, every run gets at least one lap, and that's where the percentage earns its keep.
Rebar Sizes and Weights
| Bar | Diameter | Weight per ft | 20 ft stick | Typical lap (40 d) |
|---|---|---|---|---|
| #3 | 3/8 in | 0.376 lb | 7.5 lb | 15 in |
| #4 | 1/2 in | 0.668 lb | 13.4 lb | 20 in |
| #5 | 5/8 in | 1.043 lb | 20.9 lb | 25 in |
The bar number is the diameter in eighths of an inch. In Mexico and much of Latin America the same bars are sold by the fraction (3/8", 1/2") in 12 m lengths, which is why the calculator offers a 12 m stock option.
Where Rebar Estimates Go Wrong
Forgetting the edges
The "+1" in the bar count is the bar at the far edge. Leave it out and every direction comes up one bar short. Bars should stop about 2 to 3 in from the form so they stay covered.
Thickened edges and footings
Perimeter footings usually get their own continuous bars, often two #4 bars top and bottom, plus corner bars bent around the turn. Figure that as a separate run and add it.
Chairs and dobies
The grid needs to sit up in the slab. Plan on one chair or concrete dobie every 3 to 4 ft each way. For this garage that's around 40 to 50 supports.
Practical Tips
- Stagger laps so they don't all land on the same line across the slab.
- Tie every crossing around the perimeter and every other one in the field. That's enough to hold the mat during the pour.
- Buy tie wire by the coil: a 3.5 lb coil of 16 gauge covers roughly 500 to 600 hand ties.
- Walk the mat before the truck shows up. Bent or flattened sections should be lifted back onto chairs.
Rough Cost
Grade 60 #4 rebar typically sells for around $8 to $14 per 20 ft stick at US home centers, a bit less from a steel yard by the ton. The garage slab above comes to roughly $400 to $700 in bar, plus $20 to $40 for wire and chairs. Having a supplier cut and bend bars to a schedule costs more per pound but saves a day on bigger jobs.
Sources
Frequently Asked Questions
What size rebar for a 4 inch slab?
#3 or #4 bar on 12 to 18 inch centers is typical for driveways, garage floors and patios on decent soil. Follow the plans if an engineer drew them.
How far apart should rebar be in a slab?
12 to 18 inches each way is common for residential slabs. Codes cap spacing at about 18 in or three times the slab thickness, whichever is less.
How much should rebar overlap?
A common rule is 40 bar diameters: about 15 in for #3, 20 in for #4 and 25 in for #5. Check the plans or local code for the exact lap length.
Where should rebar sit in the slab?
In the middle third of the slab, usually around 2 in from the bottom on a 4 in slab. Use chairs or concrete dobies; bar lying on the dirt does nothing.
Do I tie every intersection?
Not always. Many crews tie every other crossing in the field and every crossing around the edges. Ties only hold the grid in place during the pour.